In the world of PCB design, a strong power distribution network (PDN) is key to ensuring your board operates reliably. One critical factor in designing an effective PDN is determining the right PCB copper thickness, especially for inner layers. But how do you calculate the optimal copper thickness to balance current capacity, minimize voltage drop, and maintain power integrity? This blog post dives deep into the process, offering practical guidance for engineers and designers. We’ll break down the essentials, provide actionable steps, and share insights to help you achieve a stable and efficient power delivery system on your PCB.

Let’s get started with a clear roadmap to calculate the ideal inner layer copper thickness for your PDN, ensuring your design meets performance demands without unnecessary costs or risks.

 

Why Inner Layer Copper Thickness Matters in Power Distribution Networks

The power distribution network in a PCB is responsible for delivering stable power to all components. If the PDN fails to provide consistent voltage or handle the required current, your circuit can suffer from noise, heat buildup, or even complete failure. Inner layer copper thickness plays a huge role in this system because it directly impacts how much current the layer can carry and how much voltage drop occurs across the board.

Thicker copper layers can handle higher currents with less resistance, reducing voltage drops and heat generation. However, thicker copper also increases manufacturing costs and can complicate the design of multilayer boards. On the other hand, thinner copper layers save money but may not support the current demands of high-power applications, leading to overheating or signal integrity issues. Striking the right balance is essential for both performance and cost-efficiency.

 

Key Factors in Calculating Copper Thickness for PDN

Before diving into the calculation process, it’s important to understand the main factors that influence the choice of copper thickness in a power distribution network. These include current capacity, voltage drop, thermal management, and power integrity requirements.

1. Current Capacity

The amount of current your PCB needs to carry is a primary driver in determining copper thickness. Copper thickness is often measured in ounces per square foot (oz/ft2), where 1 oz/ft2 equals approximately 35 micrometers (μm) or 1.37 mils. A thicker copper layer can carry more current without overheating. For example, a 1 oz copper layer can safely carry around 2-3 amps for a 10-mil wide trace at room temperature, while a 2 oz layer can handle roughly double that amount under similar conditions, depending on trace width and ambient temperature.

To estimate the required current capacity, you’ll need to know the maximum current draw of your circuit. Tools like online trace width calculators or standards from the Institute of Printed Circuits (IPC), such as IPC-2221, provide guidelines for matching copper thickness and trace width to current needs.

2. Voltage Drop

Voltage drop occurs when current flows through a conductor with resistance, leading to a loss of voltage across the trace or plane. Excessive voltage drop can cause components to receive less power than needed, affecting performance. The resistance of a copper layer depends on its thickness, width, and length. Thicker copper reduces resistance, minimizing voltage drop. For instance, a 1 oz copper trace that is 100 mils long and 10 mils wide might have a resistance of about 0.05 ohms, leading to a 0.1V drop at 2 amps. Doubling the thickness to 2 oz cuts the resistance in half, reducing the drop to 0.05V.

For high-current designs, keeping voltage drop below 1-2% of the supply voltage is a common target. This often means opting for thicker copper on power planes or wider traces.

3. Thermal Management

Current flowing through copper generates heat due to resistance. If the copper is too thin for the current load, the temperature can rise significantly, risking damage to the PCB or nearby components. Thicker copper dissipates heat better because it has lower resistance and more mass to absorb thermal energy. Standards like IPC-2152 provide charts to correlate copper thickness, trace width, and temperature rise for a given current.

For example, a 1 oz copper trace carrying 5 amps might see a temperature rise of 20°C above ambient, while a 2 oz trace under the same conditions might only rise by 10°C. Proper thermal management ensures long-term reliability, especially in power-heavy applications.

4. Power Integrity

Power integrity refers to the ability of the PDN to deliver stable voltage with minimal noise or fluctuations. Thin copper layers can introduce higher impedance in the power delivery path, leading to voltage ripples or noise that affect sensitive components like microcontrollers or high-speed digital circuits. Thicker copper, combined with proper decoupling capacitors and plane design, helps maintain low impedance and ensures clean power delivery.

 

Step-by-Step Guide to Calculating Optimal Inner Layer Copper Thickness

Now that we’ve covered the key factors, let’s walk through a practical method to calculate the optimal copper thickness for inner layers in a power distribution network. This approach balances performance with manufacturability and cost.

Step 1: Determine Current Requirements

Start by identifying the maximum current your power distribution network needs to handle. Sum up the current draw of all components connected to the power plane. For example, if your board powers a microcontroller drawing 1 amp, a sensor at 0.5 amps, and a motor driver at 3 amps, your total current requirement is 4.5 amps. Add a safety margin of 20-50% to account for transients or future design changes, bringing the design target to around 5.5-6.75 amps.

Step 2: Estimate Voltage Drop Limits

Decide on an acceptable voltage drop for your design. A common rule of thumb is to keep the drop below 1-2% of the supply voltage. For a 5V system, this means a maximum drop of 0.05-0.1V. Calculate the maximum resistance your power plane or trace can have using Ohm’s Law (V = I × R). For a 6 amp current and 0.1V drop, the resistance must be below 0.0167 ohms (0.1V / 6A).

Step 3: Select Trace Width and Copper Thickness

Use a trace width calculator or refer to IPC standards to find a combination of trace width and copper thickness that meets your current and resistance requirements. For inner layers, power planes often span large areas, reducing resistance compared to narrow traces. However, if you’re routing power through traces, width matters. For instance, to carry 6 amps with a 1 oz copper layer and keep temperature rise below 10°C, you might need a trace width of 50-60 mils. If space is constrained, switching to 2 oz copper could reduce the required width to 30-40 mils.

For power planes on inner layers, resistance is lower due to the large surface area, but thickness still matters for high-current designs. A 1 oz plane might suffice for currents up to 5-10 amps in many cases, but for 20 amps or more, 2 oz or even 3 oz copper may be necessary to keep resistance and heat in check.

Step 4: Factor in Thermal Constraints

Check the expected temperature rise using IPC-2152 charts or simulation tools. If the calculated temperature rise exceeds your design limits (e.g., 20°C above ambient), increase the copper thickness or add thermal vias to dissipate heat. For inner layers, heat dissipation is harder since they’re sandwiched between other layers, so thicker copper is often the best solution.

Step 5: Verify Power Integrity Needs

Ensure the chosen copper thickness supports low impedance for power integrity. Use simulation tools to model the PDN impedance and check for voltage ripples. If impedance is too high, consider thicker copper or additional power planes. Decoupling capacitors placed near high-current components can also help stabilize voltage, reducing the burden on copper thickness alone.

Step 6: Balance Cost and Manufacturability

Finally, consider the cost implications. Standard copper thicknesses like 0.5 oz, 1 oz, and 2 oz are widely available and cost-effective for most designs. Thicker options like 3 oz or 4 oz are possible but increase manufacturing costs and may require special processes. Confirm with your PCB fabricator that your chosen thickness aligns with their capabilities for inner layers.

 

Common Copper Thickness Options for Inner Layers

Inner layer copper thickness typically ranges from 0.5 oz to 2 oz in most PCB designs. Here’s a quick overview of when to use each:

  • 0.5 oz (17.5 μm): Suitable for low-current designs or signal layers where power demands are minimal. Often used in cost-sensitive projects with currents below 1-2 amps.
  • 1 oz (35 μm): The industry standard for many applications, handling currents up to 5-10 amps on power planes with proper design. Ideal for moderate power needs.
  • 2 oz (70 μm): Used for high-current applications or when minimizing voltage drop is critical. Supports currents of 10-20 amps or more, depending on plane size.

For extremely high-power designs, such as industrial equipment or automotive systems, 3 oz or thicker copper may be necessary, though it’s less common for inner layers due to manufacturing constraints.

 

Practical Tips for Designing PDN with Optimal Copper Thickness

Beyond calculations, here are some practical tips to ensure your power distribution network performs well with the chosen copper thickness:

  • Use Power Planes: Dedicate entire inner layers to power and ground planes rather than relying solely on traces. This reduces resistance and improves power integrity.
  • Place Vias Strategically: Use multiple vias to connect power planes across layers, minimizing impedance and voltage drop at connection points.
  • Simulate Your Design: Use PDN analysis tools to simulate impedance, voltage drop, and current density. This helps identify weak points before manufacturing.
  • Consider Stackup Design: Position power and ground planes close together in the stackup to reduce loop inductance and improve noise suppression.

 

Conclusion: Building a Robust Power Distribution Network

Calculating the optimal inner layer copper thickness for a power distribution network is a critical step in PCB design. By carefully considering current capacity, voltage drop, thermal constraints, and power integrity, you can select a PCB copper thickness that ensures stable power delivery without breaking the budget. Whether you’re working on a low-power IoT device or a high-current industrial system, following a structured approach—determining current needs, estimating acceptable voltage drop, and verifying thermal and impedance requirements—will lead to a reliable and efficient design.

At ALLPCB, we’re committed to supporting engineers with the resources and manufacturing expertise needed to bring your designs to life. With a focus on precision and quality, we help you achieve the perfect balance of performance and cost in your PCB projects. Start with these guidelines, use simulation tools to validate your choices, and create a power distribution network that powers up your innovation.