Hi,
Has anyone who's using vapor phase process able to help me troubleshoot tombstoning? I raed about uneven forces during reflow due to misalignment, pad design, paste volume deposition unevenness due to dirty stencils, worn stencil printer parts such as squeegee, etc. but there was an article that pre-heating using an IR will minimise and sometimes eliminate the problem. How true is this? Has anyone had this experience with a Vapor Phase oven fitted with IR Pre-heat?