Why Freezing Rain Causes Large-Scale High-Speed Rail Delays

Author : Adrian September 25, 2025

Overview

During the Lunar New Year period, freezing rain and snow caused widespread delays for some high-speed trains in certain regions. Where does the electricity for high-speed rail come from, and why does freezing rain lead to large-scale delays? This article explains the power source for high-speed trains and the operational challenges frozen precipitation can cause.

How much power do high-speed trains use?

According to available resources, a high-speed train running at 350 km/h consumes about 9,600 kWh per hour, while one running at 250 km/h consumes about 4,800 kWh per hour. A single 250 km/h trip from Beijing to Nanjing takes roughly four hours and consumes nearly 19,200 kWh, equivalent to powering an air conditioner that uses 1 kWh per night for about 55 years.

Where does the electricity come from?

High-speed rail draws its electricity from the public power grid. High-speed rail operators are large, specialized customers of the grid; residential supply is also provided by the public utility. The electricity used by trains differs from typical grid supply mainly in voltage and phase. In China’s electrified railways, trains use single-phase alternating current at the grid frequency (50 Hz) and at voltages of 25 kV or 27.5 kV. This single-phase, high-voltage AC is derived from the grid through traction substations.

Is the train always connected to the grid while running?

Trains are not continuously electrically connected to the grid during motion. They pass through short de-energized sections, called phase breaks, located between traction substations and the line supports. These sections are typically about 100 meters long. Trains coast through these sections using inertia, so passengers normally do not notice them.

What happens if the train loses power?

Each trainset carries onboard batteries that supply power for starting systems such as the pantograph and provide emergency and auxiliary power if the external supply is interrupted. However, recent incidents have shown that freezing rain and other severe weather can damage the catenary system and pantographs. Because many lines lack redundant contact wire systems, repairs can take a long time. In addition, onboard battery capacity is often not sized to supply air-conditioning loads for extended outages.

Advice for passengers during a power outage

  • Remain calm. During a power loss, many onboard systems will not operate. China’s high-speed and intercity trains have sealed windows, and doors generally remain closed unless opening is essential for safety.
  • Drink water reasonably. In a hot, confined environment, lack of hydration can lead to heat stress or dehydration.
  • Maintain order. Stay composed and follow crew instructions while waiting for power restoration.

Why freezing rain is especially problematic

Freezing rain can damage the contact wire and can also cause pantograph components to stick, fracture, or otherwise fail. An illustrative video shows how freezing rain affects the catenary and pantograph: video

To ensure safety, operators reduce train speeds, and extensive delays or suspensions may occur during severe freezing rain events.

Recommended Reading
Benefits and Drawbacks of Smart Meters

Benefits and Drawbacks of Smart Meters

January 28, 2026

Overview of smart meter functionality, benefits, and trade-offs: accurate billing, real-time monitoring, remote readings, fault detection, network dependency, and privacy risks.

Article
Monitoring and Inspection Methods for Smart Power Grids

Monitoring and Inspection Methods for Smart Power Grids

April 27, 2026

Rail-based inspection robot systems for indoor substation monitoring, covering detection modules, mobility, thermal imaging, sensor data fusion and condition-based maintenance.

Article
What Is an Energy Storage Converter (PCS)?

What Is an Energy Storage Converter (PCS)?

April 20, 2026

Technical overview of energy storage converters (PCS): bidirectional AC/DC conversion, operating modes, topologies, protections and application scales from residential to utility.

Article
Common Causes of Circuit Breaker Trips: Case Studies

Common Causes of Circuit Breaker Trips: Case Studies

April 20, 2026

Diagnostic guide for circuit breaker trips across seven real cases, covering RCD leakage, undervoltage protection, wiring faults, conductor sizing (4 mm2) and breaker selection.

Article
Modular Switchgear Designs and Cabinet Options

Modular Switchgear Designs and Cabinet Options

April 20, 2026

Overview of modular switchgear design, SF6-insulated load switches, and automated mechanisms; guidance on ring main unit parameters, neutral grounding, and automation interfaces.

Article
Structure and Working Principle of Smart Electricity Meters

Structure and Working Principle of Smart Electricity Meters

April 15, 2026

Technical overview of smart electricity meters: architecture and metering module operation with energy metering IC, plus communication, security, storage, clock and power modules.

Article