Wearable Sensor for Detecting and Monitoring Muscle Atrophy

Author : Adrian October 31, 2025

Wearable Sensor for Detecting and Monitoring Muscle Atrophy

Overview

Researchers at Ohio State University (OSU) have developed a wearable health sensor for the detection and monitoring of human muscle atrophy.

The wearable sensor is intended to help patients track muscle health more conveniently.

Clinicians currently rely on magnetic resonance imaging (MRI) to assess muscle size and volume and to determine whether muscle atrophy is progressing. Frequent MRI, however, is time consuming and costly. According to Mems Consulting, OSU researchers recently published a study in IEEE Transactions on Biomedical Engineering proposing an electromagnetic sensor made from conductive e-threads as a potential alternative to frequent MRI monitoring.

Design and testing

The team 3D printed limb molds and filled them with ground beef to simulate the calf tissue of an average-sized human subject. The results show the wearable sensor can measure small volumetric changes in overall limb size and can monitor up to 51% muscle loss.

Lead author Allyanna Rice said the goal is for the wearable sensor to enable health care providers to implement personalized treatment plans while reducing the burden on patients.

The paper describes the first known use of a wearable device to monitor muscle atrophy, building on Rice's prior work developing health sensors for the National Aeronautics and Space Administration (NASA). NASA has an interest in multiple methods for monitoring astronaut health.

Rice added that the wearable sensor could track the health of astronauts on long missions or patients at home without medical personnel present.

Sensor construction

Rice and coauthor Asimiia Kiourti designed the device to operate using two coils and a conductor made from e-threads. The e-threads run along the fabric in a distinctive Z-shaped pattern.

Although the final product may resemble a blood pressure cuff, an early challenge was finding a way to allow large adjustments in the sensor loop size to fit most of the population.

Rice said the team realized a stretchable material was necessary once they accounted for continuous limb movement. They needed a sensor that could deform and bend while maintaining a stable shape.

Technical challenges

The main technical challenge was creating a sensor with a high degree of stretch. Stretchable electronics and conductors are an emerging area and often rely on liquid- or ink-based materials. The team preferred conductive e-threads because they have no seams and are more durable for users, but e-threads are rigid and not intrinsically stretchable. To address this, they developed a Z-shaped stitching pattern on a spandex substrate that achieved a 43% stretch ratio.

How it works

The system uses two coils: a transmitter (TX) and a receiver (RX). A time-varying current is applied to the transmitter coil, generating magnetic flux. That flux induces a measurable voltage in the receiver coil.

Induced magnetic flux depends on the coil cross-sectional area. As limb circumference increases, the total flux and voltage at the receiver coil increase. The e-threads act as the conductive "wires," and the Z-shaped stitching improves the stretchability of the conductors.

Future work

The team plans to combine the muscle-atrophy sensor with other wearable, multimodal sensing, imaging, and monitoring technologies. They are developing additional sensors based on antenna and microwave techniques. Further work to improve the muscle-atrophy sensor includes adding extra coils to increase accuracy and resolution, integrating more detailed human physiology, and replacing bulky benchtop measurement equipment.

Rice expects the next major step will likely be connecting such devices to a mobile app. She also anticipates combining these sensors with other devices to detect and monitor health issues, such as bone loss.

Rice: "In the future, we hope to integrate more sensors and more capabilities into this wearable device."

Interview excerpt

Below is a condensed version of Rice's interview with NASA Tech Briefs.

Tech Briefs: What inspired this research?

Rice: Our work was funded by NASA's Space Technology Graduate Research Opportunities scholarship. Initially, we focused on solutions for various health issues astronauts face during long-duration spaceflight. In microgravity, astronauts experience significant muscle atrophy even over relatively short mission periods.

Our goal was to design a lightweight, portable, wearable health sensor for frequent monitoring of muscle atrophy. Muscle atrophy also affects patients on Earth with conditions such as cancer, aging, neurological disorders, or those who spend extended periods in intensive care units (ICU). We aimed to develop a sensor suitable for most of the general population and several specific use cases.

Tech Briefs: What was the biggest technical challenge?

Rice: The biggest challenge was manufacturing a highly stretchable sensor. Stretchable electronic devices and conductors are an emerging field, typically relying on liquid- or ink-based materials. We wanted to use conductive e-threads because they have no seams and are more durable for users. However, e-threads are rigid and not stretchable by themselves. We therefore designed a new Z-shaped stitching pattern using e-threads on spandex to achieve a 43% stretch.

Tech Briefs: Can you briefly explain how the technology works?

Rice: The system consists of two coils: a transmitter (TX) and a receiver (RX). We apply a time-varying current to the transmitter coil to create magnetic flux, which induces a measurable voltage in the receiver coil.

Induced magnetic flux depends on the coil's cross-sectional area. Therefore, as limb circumference increases, the total flux and voltage on the receiver coil increase. The e-threads serve as the conductive "wires," and the Z-shaped stitching enhances the wires' stretchability.

Tech Briefs: What are your next steps?

Rice: We plan to combine the muscle-atrophy sensor with other wearable multimodal sensing, imaging, and monitoring sensors. We are developing additional sensors based on antenna and microwave techniques. To improve the muscle-atrophy sensor further, we will add extra coils to improve accuracy and resolution, integrate more specific human physiology, and replace bulky benchtop equipment.

Tech Briefs: Any advice for engineers pursuing their ideas?

Rice: Don't be afraid to imagine boldly and pursue every interesting idea. Also, expect many trials, errors, and failures before achieving success.

Recommended Reading
How Smartwatches Monitor Sleep

How Smartwatches Monitor Sleep

October 31, 2025

Overview of how wearables use actigraphy and cardiopulmonary coupling (CPC) to infer sleep stages, assess deep sleep accuracy, and enable at-home physiological sleep monitoring.

Article
Smartwatch and Patch Using a Piezoelectric Blood Pressure Sensor

Smartwatch and Patch Using a Piezoelectric Blood Pressure Sensor

October 31, 2025

KAIST-developed wearable piezoelectric blood pressure sensor validated in clinical trials, meeting accuracy standards and integrated into smartwatch and patch prototypes.

Article
Wearable Bistable Triboelectric Generator for Low-Frequency Harvesting

Wearable Bistable Triboelectric Generator for Low-Frequency Harvesting

October 31, 2025

Wearable bistable triboelectric nanogenerator using a flexible negative-stiffness mechanism to harvest low-frequency torsional energy from human motion and power low-power sensors.

Article
Skin-Integrated PPG-ECG Multimodal Sensing Patch Design

Skin-Integrated PPG-ECG Multimodal Sensing Patch Design

October 02, 2025

Skin-integrated PPG-ECG patch using ultraflexible organic photodetectors and hydrogel electrodes to monitor HR, RR, cuffless BP and SpO2 with high NIR responsivity.

Article
Multimodal Wearable Sensor Patch for Continuous Plant Monitoring

Multimodal Wearable Sensor Patch for Continuous Plant Monitoring

October 02, 2025

Multimodal wearable sensor patch for continuous plant physiology monitoring detects leaf VOCs, temperature and humidity; PCA-based ML enables earlier disease and stress detection.

Article
Flexible Wearable Optical Wireless Sensor for Fruit Quality

Flexible Wearable Optical Wireless Sensor for Fruit Quality

October 02, 2025

Flexible wearable optical wireless sensing (FWOS) system using laser-patterned PET/PI/Cu circuits and AS7263 NIR sensors for real-time fruit quality monitoring via Bluetooth.

Article